product

We are the industry standard

One of the key strengths provided by Envirotank is industry leadership. All Envirotank products meet or exceed industry and regulatory standards. We were the first and are the technology leaders in the underground petroleum tank industry. We are fully licensed and hold many patents on products and accessories we offer. Our tanks have become the standard in the petroleum industry uses when underground storage is specified.

 

product

ENVIROTANK DOUBLE-WALL TANKS DELIVER STATE-OF-THE-ART PROTECTION

With more alternative fuels being introduced to the marketplace and steel tank providers decreasing warranties due to corrosion issues, fuel storage decisions can get complicated.

Envirotank is here to simplify the problem. Envirotank manufactures the finest quality fuel storage tanks for underground systems. Our double-wall fiberglass tanks are inherently non-corrosive, safely storing standard petroleum fluids, biofuels and biodiesels, ethanol and ethanol blends, ultra-low sulphur diesel (ULSD) and even diesel exhaust fluid (DEF). Many of the newest industry fuels and bio fuels are alcohol based.

Alcohol blends, including ethanol, increase the likelihood of water in a storage tank, resulting in rust and microbial-induced corrosion (MIC) in jacketed steel tanks and unlike underground jacketed steel tanks, Envirotank fuel storage tanks are backed by an industry best 30-year internal corrosion warranty.

Envirotank is a trusted name with a proven and dependable product. The inherent non-corrosive nature of an Envirotank double-wall tank eliminates the possibility of rust on all tank wall surfaces. With more than 300,000 tanks installed around the world, Envirotank is the preferred technology and the industry leader.

product

Double walled Envirotanks for petroleum storage are designed for the storage of petrol, alcohol blended petrol (with up to 100% methanol or ethanol), jet fuel, av-gas, motor oil, kerosene, diesel fuel, bio-diesel blends, diesel exhaust fluid, oxygenated fuels (with up to 20% MTBE), or potable water at ambient underground temperatures. Fuel oil may be stored at temperatures not to exceed 65°C. The storage of other liquids may result in tank failure. Before storing liquids other than those listed above, contact Envirotank for further guidance.

 

PDF Petroleum Brochure

product

HYDROGUARD® HYDROSTATIC MONITORING

The Hydroguard® Hydrostatic Monitoring System assures you of product tightness

Hydrostatic Monitoring detects leaks in either the primary or secondary tank walls in all installed conditions. First the cavity between the inner and outer walls, known as the annular space, is filled with monitoring fluid. Hydrostatic pressure is then applied to the annular space enabling monitoring of both the primary containment and the secondary containment areas. This means that 100% of the storage area is monitored at all times.

Continuous monitoring and precision tank-testing capabilities are built into every Envirotank.

  • Non-toxic water based food dye.

  • Prior to and during installation tank integrity monitoring.

  • Continuous monitoring in all installed conditions.

  • Optional third party electronic sensors for remote monitoring.

Because it is comforting to be able to test the ongoing integrity of any storage tank, Envirotank built into each of our double-wall tanks both continuous monitoring and precision tank-testing capabilities. Our tanks are supplied with a factory installed Hydroguard® Monitoring System with a coloured monitoring fluid. The fluid is a dark blue colour preinstalled in the interstitial space at the factory and is used to perform visual leak testing during shipment and at the jobsite.

We recommend the Hydroguard® Monitoring System because it offers a leak detection capability that is superior to other methods. It constantly monitors 100% of both the inner and outer walls under all installed conditions.

 

 How Hydroguard Works

product

PETROLEUM STORAGE: DOUBLE-WALL STORAGE TANKS - SPECIFICATIONS

Envirotank Standard Tank Range

Nom.Capacity
(Litres x 1000)

Length
L(OA)

ID-Inside
Diameter

OD-Outside
Diameter

Approx. Weight

5

4800

1200

1290

750

10

3950

2000

2090

1050

20

4700

2500

2590

1550

30

6750

2500

2590

2200

40

8750

2500

2590

2850

45

9750

2500

2590

3150

50

10800

2500

2590

3450

55

11800

2500

2590

3750

60 (2.5m)

12800

2500

2590

4200

60 (3.0m)

9050

3000

3125

4200

70 (2.5m)

14800

2500

2590

5200

70 (3.0m)

10600

3000

3125

5200

80

11950

3000

3125

6200

90

13500

3000

3125

6500

100

14850

3000

3125

6800

110

16400

3000

3125

7500

Specific tank sizes and drawings are available on request. Envirotank shall provide fibreglass underground storage tanks in sizes and with fittings as shown on the drawings provided. The tanks shall be manufactured by Envirotank to meet the requirements of all the relevant standards and codes.